Vista de página 0
9 V Battery-Operated
Dual Sensor
Smoke Alarm
Photoelectric / Ionization with Hush
®
Alarm Manual
Model PI9000CA
Manual P/N 820-1062 Rev. A
SINGLE STATION
SMOKE ALARM
Ionization sensing alarms may detect invisible fire
particles (associated with fast flaming fires) sooner
than photoelectric alarms. Photoelectric sensing
alarms may detect visible fire particles (associated
with slow smoldering fires) sooner than ionization
alarms. Home fires develop in different ways and
are often unpredictable. For maximum protection,
Kidde recommends that both Ionization and
Photoelectric alarms be installed.
Vista de página 0
1 2 3 4 5 6 ... 19 20

Resumo do Conteúdo

Página 1 - Dual Sensor

9 V Battery-OperatedDual SensorSmoke AlarmPhotoelectric / Ionization with Hush®Alarm ManualModel PI9000CAManual P/N 820-1062 Rev. ASINGLE STATIONSMOKE

Página 2 - Introduction

Installation9BatteryThis unit will not function without a properly installedbattery. When installing a battery, press the batteryreminder tab down int

Página 3

Operation10Hush®Control FeatureSmoke alarms are designed to minimize nuisance alarms.Cigarette smoke will not normally set off the alarm, unlessthe sm

Página 4

Operation11Alarm Tamper-Resist FeatureThis alarm has a tamper-resist feature. This feature willhelp deter children or others from removing the alarmfr

Página 5

Operation12LED IndicatorsThis smoke alarm is equipped with a red LED indicator.The red LED is located under the test button and hasseveral modes of op

Página 6

Operation13TestingTest by pushing the Test button on the cover and hold itdown for a minimum of 5 seconds. This will sound thealarm if all the electro

Página 7

MaintenanceAfter installing or changing the battery, reinstall your alarm andtest your alarm by using the test button.WARNING! Use only the batteries

Página 8

Fire SafetyLimitations of Smoke AlarmsWARNING: Please read carefully and thoroughly.• NFPA 72 states: Life safety from fire in residential occupancies

Página 9 - InstallRemove

16Fire Safety• If the alarm is located outside the bedroom or on adifferent floor, it may not wake up a sound sleeper.• The use of alcohol or drugs ma

Página 10 - Operation

Fire Safety17What To Do When The Alarm Sounds• Alert small children in the home.• Leave immediately by your escape plan. Every secondcounts, so don’t

Página 11

Additional RecommendationsThe National Fire Protection Association’s Standard 72provides the following information:Smoke alarms shall be installed out

Página 12

Introduction . . . . . . . . . . . . . . . . . . . . . . . . 1Installation . . . . . . . . . . . . . . . . . . . . . . . . . . 2–9Operation . . . . .

Página 13

19If after reviewing this manual you feel that your smokealarm is defective in any way, do not tamper with the unit.In many cases, the quickest way to

Página 14 - Maintenance

This product is designed to detect products of combustionusing both an ionization sensor and a photoelectric sensor.The ionization sensor contains 0.9

Página 15

Recommended Locations• Locate the first alarm in the immediate area of thebedrooms. Try to monitor the exit path, as thebedrooms are usually farthest

Página 16 - Fire Safety

• Install smoke alarms on sloped, peaked or cathedralceilings at or within 0.9 m (3') of the highest point(measured horizontally). NFPA Standard

Página 17

Locations to Avoid• Do not install within 0.9 m (3') of the following: Thedoor to a kitchen, or a bathroom that contains a tub orshower, forced a

Página 18

Installation6IMAGE 2AIMAGE 2CIMAGE 2BHORIZONTAL DISTANCE FROM PEAKCEILING10 cm (4”)MINIMUM10 cm (4”)MINIMUM30.5 cm (12”)MAXIMUMSIDE WALLBESTPLACEMENTA

Página 19

Mobile HomesModern mobile homes have been designed to be energyefficient. Install smoke alarms as recommended inRecommended Locations and Image 2A.In

Página 20 - Warranty

Installation8• Install the alarm on the mounting plate and rotate thealarm in the direction of the “ON” arrow on the coveruntil the alarm ratchets int